What we do

ENGINEEREDPROTECTION

Four field-tested services covering the full lightning protection and grounding lifecycle — designed in-house, installed by our own crews, verified to local and international standards. One accountable team, concept to completion.

S/01 Engineering & Installation

Lightning protection, designed before it's built.

Our in-house engineering team produces customized direct-strike lightning protection using both ESE (Early Streamer Emission) methodology to NF C 17-102 and Conventional methodology to NFPA 780, validated by a full risk assessment to local and international standards, before a single bolt is set.

ESE methodology · NF C 17-102 Conventional methodology · NFPA 780 VS430 · Grounding column Risk assessment · IEC 62305-2
Strike-zone modeling — every protected volume calculated, not estimated.
Formal risk assessment aligned to IEC 62305-2, with a signed engineer's report.
Single-contract delivery — engineering, procurement, and installation under one accountable team.
As-built documentation ready for handover, audit, and insurance.
Talk to an engineer Outcome · IEC 62305 compliant design
Strike Protection
01
Design methodology
ESENF C 17-102
ConventionalNFPA 780
Grounding columnVS430

Both air-termination methods modeled against your structure — the risk assessment decides which one protects it.

S/02 Verification & Reporting

Prove the earth path. Get the numbers in writing.

A grounding system is only as good as its measured resistance to earth. Energynet runs both Fall-of-Potential and Clamp-On testing on site, then issues an engineer-signed report with the figures, the method, and a pass/fail against your facility's required threshold — the peace of mind of knowing you're truly protected.

Fall-of-Potential (3-point) Clamp-On testing IEEE 81 procedure Signed report
On-site measurement by a certified engineer.
Two test methods — Fall-of-Potential where geometry allows, Clamp-On for live installations.
Pass / fail verdict against the threshold your standard requires.
Audit-ready report with raw readings, soil conditions, and remediation notes.
Outcome · Engineer-signed test record
Test & Verify
02
Typical target
< 5 Ω

Resistance to earth for general lightning protection. Critical sites and substations may demand tighter.

Standard reference
Test procedureIEEE 81
AcceptancePer facility spec
S/03 Design & Installation

Grounding systems designed for the site they sit in.

Soil resistivity, footprint, equipment count — every site grounds differently. Energynet's in-house design service produces a system tailored to your facility's electrical load and soil profile, then installs and commissions it to the target resistance-to-earth.

Soil resistivity survey Rod & mesh design Bonding network Testing & commissioning
Site-specific design sized from real soil readings, not a generic template.
Bonding strategy for structure, equipment, and lightning protection — all on one reference.
Testing & commissioning — electrode array and bonding installed, then verified against the design threshold.
Stamped design package — drawings, BOM, and target resistance, ready for build and audit.
Outcome · Designed system + PM schedule
Grounding
03
PM cadence
Annual + post-event

Scheduled testing once a year, plus immediate post-storm inspection on subscribed sites.

S/04 Lifecycle Care

The system you installed years ago — still doing its job?

Lightning protection and grounding installations degrade quietly: bolts loosen, conductors corrode, soil dries out, resistance climbs. Our preventive maintenance program inspects, tests, and re-certifies your existing systems — even if we didn't install them — so you keep the protection you paid for.

Annual inspection Continuity check Ground re-test Corrosion audit Post-storm callout
Takeover service — we'll inspect, document, and adopt systems installed by others.
Scheduled visits — annual or semi-annual cadence, with calendar coordination ahead of storm season.
Repair quote issued on the same visit if remediation is required.
Audit-ready file — annual certificate, raw test data, photographic record.
Outcome · Annual certificate of compliance
Maintenance
04
Typical PM contract
Cadence1× / year
Visit duration4 – 8 hrs
System warranty5 years
DeliverableSigned certificate
How we work

One team, four phases, signed off at every gate.

Energynet runs every engagement under one contract — engineering, procurement, construction. You sign one scope, deal with one accountable PM, and get one as-built file at the end.

01
Day 0 – 5

Site survey

Engineer on site, soil resistivity readings, structure walk-down, existing-system audit if applicable.

02
Week 1 – 3

Engineered design

Risk assessment, stamped drawing set, BOM, and a fixed quote.

03
Scope-dependent

Procurement & install

Energynet supplies materials and runs the install with our own crews. Daily progress reports, weekly site walks.

04
Pre-handover

Verify & certify

Ground resistance test, continuity verification, as-built drawings, engineer-signed certificate of compliance.

Designed & assessed to
IEC 62305 / Lightning protection NFPA 780 / Installation IEEE 81 / Ground measurement PEC / Philippine Electrical Code
Why Energynet

Three reasons clients pick us over a regular contractor.

Lightning and grounding are safety-critical. The wrong shortcut is the kind of mistake you only notice during a storm. Here's what changes when you engage a specialist.

PILLAR / 01

Engineering done in-house

Design, risk assessment, and BOM are produced by Energynet's own engineers — not outsourced or rubber-stamped. Every drawing has someone you can call.

100% In-house engineering
PILLAR / 02

One contract, one team

Single-contract delivery means engineering, procurement, and installation are one accountable scope. No finger-pointing between vendors when something needs to be fixed on site.

1 Project manager, end to end
PILLAR / 03

Verified, not assumed

Every install is tested and certified before handover, and every PM visit re-measures resistance against your target. We hand you numbers, not assurances.

48 hrs Avg. proposal turnaround
Most scoped proposals come back within two business days of receiving your site information. Larger engagements requiring an in-person survey may take a week — we'll confirm the timeline as soon as we receive your request, so you're never waiting in the dark.
Yes — this is one of our most common engagements. We start with a takeover inspection (audit drawings, continuity, ground resistance, corrosion check), then move the system onto our annual PM schedule with full documentation.
A conventional Franklin rod relies on geometry alone. ESE (Early Streamer Emission) is engineered to release an upward leader earlier, enlarging the protected volume from a single mast. Both can be valid — we pick based on the structure, the risk assessment, and the standard your facility designs to.
For live installations, Clamp-On testing measures loop resistance without disconnecting the earth conductor. For new installs or where geometry allows, we use Fall-of-Potential per IEEE 81. We'll choose the right method on the survey call.
IEC 62305 and NFPA 780 for lightning protection, the Philippine Electrical Code (PEC) for installation, and IEEE 81 for ground resistance measurement. We can also align to client-specific corporate standards on request.
Ready to scope it?